| Products>>Water Monitoring Systems(Starflow) |
| >>Starflow Systems MODEL: 6526E |
| |
 |
- Features
- Velocity, depth, computed fl ow and temperature
- Integrated Micrologger
- Compatible with Starlog
- SDI-12 communications
- LCD option available
|
The ultrasonic Doppler instrument is a compact, easy to use system for measuring the velocity and depth of water in rivers and streams, open drainage channels and large pipes.
It is suitable for use in a wide range of water qualities ranging from sewerage and waste water to clean streams, potable water, and even sea water. The instrument measures forward and reverse fl ow conditions and may be programmed to compute fl ow rate and total fl ow in pipes and open channels. The newest model, the 6526D, consists of a new depth sensor in addition to all the previous features. The ultrasonic transducer assembly is profi led to reduce fl ow disturbance and signal electronics. It is designed to be placed at (or near) the bottom of the water channel for upstream measurement. A single cable connects the instrument to a 12V DC power source.
Water velocity is measured by the ultrasonic Doppler principle which relies on suspended particles or small air bubbles in the water to refl ect the ultrasonic detector signal. The instrument will not operate in very clean, degassed water. Water depth is gauged by a hydrostatic pressure sensor, referenced to atmospheric pressure through the vented power and signal cable. |
| Specifications |
| |
Velocity |
| |
|
Range: |
21 mm/s to 4500mm/s bi-directional |
| |
|
Accuracy: |
2% of measured velocity |
| |
|
Resolution: |
1mm/s |
| |
Depth |
| |
|
0 to 5 m in two ranges |
| |
Resolution |
| |
|
Range: |
0 to 2.5 M: 2.5mm |
| |
|
Range: |
2.5 to 5.0 M: 5.0 mm |
| |
|
Accuracy: |
¡À0.25% |
| |
Temperature |
| |
|
Temperature: |
-17¡ã to 60¡ãC |
| |
|
Resolution: |
0.1¡ãC |
| |
Flow |
| |
|
Computation: |
Flow rate, totalised fl ow |
| |
|
Channel type: |
Pipe, open channel, natural stream |
| |
Integrated MicroLogger |
| |
|
Storage Memory: |
100KB, CMOS RAM |
| |
|
Log interval: |
Programmable, fi ve seconds to one week |
| |
|
SDI-12: |
1200 bps instrument channel |
| |
|
Communication: |
RS-232, 300-38400 bps |
| |
|
Control: |
CMOS output trigger (water sampler) |
| |
General |
| |
|
Cable: |
15 metre, 9 way vented, <<SQL>> compatible |
| |
|
Power source: |
External battery 12V DC |
| |
|
Power usage: |
11.5 to 15V DC, 50¦ÌA standby, 200mA active, 90mA communications |
| |
|
Operating Temp: |
0¡ãC to 60¡ãC water temperature |
| |
|
Material: |
PVC body, stainless steel mounting plate |
| |
|
Dimensions: |
290mm L x 70mm W x 30mm H |
| |
|
Weight: |
1kg (2kg with 15m cable) |
|
|
| |
|
|
|
| COMPANY INFORMATION |
| Telphone |
+86-10-8857 0030 |
| Fax |
+86-10-8857 0162 |
| Mobile |
(0) 1390 136 5491 |
| E-Mail |
sales@vibtel.com |
|
|